OEM Earth Leakage Circuit Breaker Suppliers – 1P, 2P, 3P, 4P B C D curve, MCB, ETM3, AC, DC, miniature circuit breaker, mini circuit breaker, din rail – Etechin
OEM Earth Leakage Circuit Breaker Suppliers – 1P, 2P, 3P, 4P B C D curve, MCB, ETM3, AC, DC, miniature circuit breaker, mini circuit breaker, din rail – Etechin Detail:
Products Description
ETM3 series MCB is in complied with IEC 60898-1 standard. It has the certification of Dekra / KEMA, CE and CB .
The breaking capacity of ETM3 is 10KA, or 6KA.
The tripping type is B, C, D curve.
The rated current is (1A, 2A, 3A, 4A) 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A. The rated current is related to different area using for example one pole 10 to 16 ampere is normally used for lighting, 20 ampere to 33 ampere is normally used for kitchen and bathroom area, also used for air conditioner and other line equipment. Some customers will choose 2 pole, 40ampere to 63 ampere as main switch instead of isolator.
The tripping type is B, C, D curve.
Rated insulation voltage: AC, 230V, 240V, 230 / 240V (1 Pole); 400 / 415V (2 poles, 3 poles). DC, 250V 1P, 500V 2P, 750V 3P, 1000V 4P.
It has single pole (1p), double poles (2p), three poles (3p), and four poles(4p).
There is a position indicator equipped on the products, Red is on, Green is off.
The MCB terminals are IP20 protection which is designed for finger and hand touch safe to keep the safety during installation.
The ETM3 MCB can work reliably in harsh environment, in ambient temperature from -25°C to 55°C.
The electrical life can be up to 8000 operations and mechanical life up to 20000 operations, while the IEC requirement is only 4000 operations and 10000 operations.
It’s mounting type is to be mounted on din rail EN60715 35mm.
Technical Characteristic
Standard |
IEC/EN 60898-1 |
||
Electrical |
Rated current in |
A |
( 1 2 3 4) 6 10 16 20 25 32 40 50 63 |
features |
Poles |
1P 2P 3P 4P |
|
Rated voltage Ue |
V |
230/400,240/415 |
|
Insulation coltage Ui |
V |
500 |
|
Rated frequency |
Hz |
50/60Hz |
|
Rated breaking capacity |
A |
4.5/6/10KA |
|
Rated impulse withstand voltage (1.2/50)Uipm |
V |
6000 |
|
Dielectric test voltage at and ind.Freq.for 1min |
KV |
2 |
|
Pollution degree |
2 |
||
Themo-magnetic release characteristic |
B C D |
||
Mechanical |
Electrical life |
above 4000 |
|
features |
Machanical life |
above 10000 |
|
Contact position indicator |
Yes |
||
Protection degree |
IP 20 |
||
Reference temperature of setting of thermal element |
°C |
30 or 50 |
|
Ambient temperature(with daily average≤35°C) |
°C |
-25~+55 |
|
Storage temperature |
°C |
-25…+70 |
|
Installation |
Terminal connection type |
Cable/U-type busbar/Pin-type busbar |
|
Terminal size top/bottom for cable |
mm² |
25 |
|
AWG |
18-3 |
||
Terminal size top/bottom for busbar |
mm² |
25 |
|
AWG |
18-3 |
||
Tightening torque |
N*m |
3.0 |
|
In-lbs. |
22 |
||
Mounting |
OnDIN rail FN 60715(35mm) |
||
by means of fast clip device |
|||
Connection |
From top and bottom |
Product detail pictures:
Related Product Guide:
During the past few years, our business absorbed and digested state-of-the-art technologies the two at home and abroad. Meanwhile, our firm staffs a group of experts devoted to your development of OEM Earth Leakage Circuit Breaker Suppliers – 1P, 2P, 3P, 4P B C D curve, MCB, ETM3, AC, DC, miniature circuit breaker, mini circuit breaker, din rail – Etechin , The product will supply to all over the world, such as: Thailand, Brazil, Finland, Based on experienced engineers, all orders for drawing-based or sample-based processing are welcomed. We have now won a good reputation for outstanding customer service among our overseas customers. We will continue to try the best to supply you good quality products and solutions and the best service. We've been looking forward to serving you.
By Paula from Brazil - 2018.07.27 12:26
We feel easy to cooperate with this company, the supplier is very responsible, thanks.There will be more in-depth cooperation.
By Agnes from Angola - 2017.09.26 12:12