page_banner

OEM 10 Amp Rcbo Manufacturer – 1P+N, RCBO, B, C curve,ETM8RF , Residual Current Breaker with Over-Current protection, din rail – Etechin

OEM 10 Amp Rcbo Manufacturer – 1P+N, RCBO, B, C curve,ETM8RF , Residual Current Breaker with Over-Current protection, din rail – Etechin


Product Detail

Product Tags

Related Video

Feedback (2)

We are convinced that with joint endeavours, the small business between us will bring us mutual benefits. We could assure you products quality and competitive selling price for Leakage Circuit Breaker, Busbar Mcb, 1p Ac Mini Circuit Breaker, We persistently develop our enterprise spirit "quality lives the enterprise, credit assures cooperation and keep the motto in our minds: customers first.
OEM 10 Amp Rcbo Manufacturer – 1P+N, RCBO, B, C curve,ETM8RF , Residual Current Breaker with Over-Current protection, din rail – Etechin Detail:

Products Description

ETM8RF series RCBO are applicable to the low-voltage terminal distribution in the industry, civil building such as home and residence, energy, communication, infrastructure, lighting distribution system or motor distribution and other fields. They provide leakage protection, short-circuit protection, overload protection, and isolation protection, which can protect the human from hurting caused by leakage of current, at the main while they can protect the circuit and appliances from the secondary accident caused by overload and short circuit.

ETM8RF series RCBO is in complied with IEC 61009-1standard.
The breaking capacity of ETM8RF is 10KA, or 6KA
The tripping type of short circuit is B, C curve.
The rated current is 6A, 10A, 16A, 20A, 25A, 32A, 40A. The rated current is related to different area using for example one pole 10 to 16 ampere is normally used for lighting, 20 ampere to 33 ampere is normally used for kitchen and bathroom area, also used for air conditioner and other equipment.
The sensitivity current of Residual Current, or Earth Leakage tripping is 10mA, 30mA, 100mA, while 10mA and 30mA is mainly used in circuit of bath room and kitchen to protect the human from electric shock.
The tripping type of Residual current is AC or A class. AC class Tripping is ensured for sinusoidal, alternating currents, whether they be quickly applied or slowly increase . A class Tripping is ensured for sinusoidal, alternating residual currents as well as for pulsed DC residual currents, whether they be quickly applied or slowly increase .
Rated voltage: 230V/ 240V ( Phase & Neutral)
There is a position indicator equipped on the products, Red is on, Green is off.
The RCBO terminals are IP20 protection which is designed for finger and hand touch safe to keep the safety during installation.
The ETM8RF RCBO can work reliably in harsh environment, in ambient temperature from -25°C to 55°C.
The electrical life can be up to 8000 operations and mechanical life up to 20000 operations, while the IEC requirement is only 4000 operations and 10000 operations.
It’s mounting type is to be mounted on din rail EN60715 35mm.

vsasv

What is RCBO?

RCBO stands for Residual Current Breaker with Over-Current protection. The RCBO combines the functionality of an MCB and RCD/RCCB. When there is a current leakage, the RCBO trips the entire circuit. Consequently, internal magnetic/thermal circuit breaker components can trip the electronic device when the circuit is overloaded.

1. Residual Current, or Earth Leakage – Occurs when there is an accidental break in a circuit through poor electrical wiring or DIY accidents such as drilling through a cable when mounting a picture hook or cutting through a cable with the lawn mower. In this instance the electricity must go somewhere and choosing the easiest route travels through the lawnmower or drill to the human causing electric shock.
2. Over-Current takes two forms:
a. Overload – Occurs when too many devices are in use on the circuit, drawing an amount of power which exceeds the capacity of the cable.
b. Short Circuit – Occurs when there is a direct connection between the live and neutral conductors. Without the resistance provided by the normal circuit integrity, electrical current rushes around the circuit in a loop and multiplies the amperage by many thousand times in just milliseconds and is considerably more dangerous than Overload.

Whereas an RCCB is designed solely to protect against earth leakage and an MCB protects only against over-current, an RCBO protects against both types of fault.

In real life, electrical components such as residual current circuit breakers (commonly known as leakage switches) are used in almost every place with electricity. It is mainly used to detect the residual current, compare the residual current value with the reference value, and disconnect the main circuit contact when the residual current value exceeds the reference value. When personal electric shock or grid leakage current exceeds the specified value, the residual current circuit breaker can quickly cut off the faulty power supply in a very short period of time, protect the safety of personal and electrical equipment, and at the same time protect the overload or short circuit of the line and motor, and also It can be used for infrequent switching of lines and infrequent starting of motors, and is a widely used electrical appliance in production and life.

1. The leakage protection relay refers to a leakage protection device that has the function of detecting and judging leakage current, but does not have the function of cutting off and connecting the main circuit. The leakage protection relay is composed of zero-sequence transformer, release and auxiliary contact for output signal. It can cooperate with the automatic switch of high current as the general protection of low-voltage power grid or the leakage, grounding or insulation monitoring protection of main road. When there is leakage current in the main circuit, since the auxiliary contact and the separation release of the main circuit switch are connected in series to form a circuit, the auxiliary contact is connected to the separation release and disconnects the air switch, AC contactor, etc. loop. Auxiliary contacts can also be connected to sound and light signal devices to issue a leakage alarm signal to reflect the insulation status of the line. 2. The leakage protection switch means that it can not only turn on or off the main circuit like other circuit breakers, but also has the function of detecting and judging leakage current. When leakage or insulation damage occurs in the main circuit, the leakage protection switch can be based on The switching element that turns the main circuit on or off as a result of the judgment. It cooperates with fuses and thermal relays to form a fully functional low-voltage switch element.


Product detail pictures:

OEM 10 Amp Rcbo Manufacturer –  1P+N, RCBO, B, C curve,ETM8RF , Residual Current Breaker with Over-Current protection, din rail – Etechin detail pictures

OEM 10 Amp Rcbo Manufacturer –  1P+N, RCBO, B, C curve,ETM8RF , Residual Current Breaker with Over-Current protection, din rail – Etechin detail pictures

OEM 10 Amp Rcbo Manufacturer –  1P+N, RCBO, B, C curve,ETM8RF , Residual Current Breaker with Over-Current protection, din rail – Etechin detail pictures

OEM 10 Amp Rcbo Manufacturer –  1P+N, RCBO, B, C curve,ETM8RF , Residual Current Breaker with Over-Current protection, din rail – Etechin detail pictures

OEM 10 Amp Rcbo Manufacturer –  1P+N, RCBO, B, C curve,ETM8RF , Residual Current Breaker with Over-Current protection, din rail – Etechin detail pictures


Related Product Guide:

We know that we only thrive if we will guarantee our combined cost competiveness and high-quality advantageous at the same time for OEM 10 Amp Rcbo Manufacturer – 1P+N, RCBO, B, C curve,ETM8RF , Residual Current Breaker with Over-Current protection, din rail – Etechin , The product will supply to all over the world, such as: Nigeria, London, Karachi, Customer satisfaction is our first goal. Our mission is to pursue the superlative quality, making continual progress. We sincerely welcome you to make progress hand in hand with us, and construct a prosperous future together.
  • The factory has advanced equipment, experienced staffs and good management level, so product quality had assurance, this cooperation is very relaxed and happy!
    5 Stars By Helen from Macedonia - 2018.09.23 17:37
    The factory workers have rich industry knowledge and operational experience, we learned a lot in working with them,we are extremely grateful that we can encount a good company has excellent wokers.
    5 Stars By Michelle from Mauritania - 2017.11.11 11:41
    Write your message here and send it to us